Server IP : 172.67.216.182 / Your IP : 172.71.124.58 Web Server : Apache System : Linux krdc-ubuntu-s-2vcpu-4gb-amd-blr1-01.localdomain 5.15.0-142-generic #152-Ubuntu SMP Mon May 19 10:54:31 UTC 2025 x86_64 User : www ( 1000) PHP Version : 7.4.33 Disable Function : passthru,exec,system,putenv,chroot,chgrp,chown,shell_exec,popen,proc_open,pcntl_exec,ini_alter,ini_restore,dl,openlog,syslog,readlink,symlink,popepassthru,pcntl_alarm,pcntl_fork,pcntl_waitpid,pcntl_wait,pcntl_wifexited,pcntl_wifstopped,pcntl_wifsignaled,pcntl_wifcontinued,pcntl_wexitstatus,pcntl_wtermsig,pcntl_wstopsig,pcntl_signal,pcntl_signal_dispatch,pcntl_get_last_error,pcntl_strerror,pcntl_sigprocmask,pcntl_sigwaitinfo,pcntl_sigtimedwait,pcntl_exec,pcntl_getpriority,pcntl_setpriority,imap_open,apache_setenv MySQL : OFF | cURL : ON | WGET : ON | Perl : ON | Python : OFF | Sudo : ON | Pkexec : ON Directory : /www/server/mysql/src/mysql-test/suite/sys_vars/t/ |
Upload File : |
############## mysql-test\t\net_write_timeout_basic.test ############### # # # Variable Name: net_write_timeout # # Scope: GLOBAL | SESSION # # Access Type: Dynamic # # Data Type: numeric # # Default Value: 60 # # Min Value: 1 # # # # # # Creation Date: 2008-02-07 # # Author: Salman # # # # Description: Test Cases of Dynamic System Variable net_write_timeout # # that checks the behavior of this variable in the following ways# # * Default Value # # * Valid & Invalid values # # * Scope & Access method # # * Data Integrity # # # # Reference: http://dev.mysql.com/doc/refman/5.1/en/ # # server-system-variables.html # # # ############################################################################### --source include/load_sysvars.inc ################################################################# # START OF net_write_timeout TESTS # ################################################################# ############################################################# # Save initial value # ############################################################# SET @start_global_value = @@global.net_write_timeout; SELECT @start_global_value; SET @start_session_value = @@session.net_write_timeout; SELECT @start_session_value; --echo '#--------------------FN_DYNVARS_112_01-------------------------#' ################################################################# # Display the DEFAULT value of net_write_timeout # ################################################################# SET @@global.net_write_timeout = 100; SET @@global.net_write_timeout = DEFAULT; SELECT @@global.net_write_timeout; SET @@session.net_write_timeout = 200; SET @@session.net_write_timeout = DEFAULT; SELECT @@session.net_write_timeout; --echo '#--------------------FN_DYNVARS_112_02-------------------------#' ################################################################# # Check the DEFAULT value of net_write_timeout # ################################################################# SET @@global.net_write_timeout = DEFAULT; SELECT @@global.net_write_timeout = 60; SET @@session.net_write_timeout = DEFAULT; SELECT @@session.net_write_timeout = 60; --echo '#--------------------FN_DYNVARS_112_03-------------------------#' ########################################################################### # Change the value of net_write_timeout to a valid value for GLOBAL Scope # ########################################################################### SET @@global.net_write_timeout = 1; SELECT @@global.net_write_timeout; SET @@global.net_write_timeout = 60020; SELECT @@global.net_write_timeout; SET @@global.net_write_timeout = 65535; SELECT @@global.net_write_timeout; --echo '#--------------------FN_DYNVARS_112_04-------------------------#' ############################################################################ # Change the value of net_write_timeout to a valid value for SESSION Scope # ############################################################################ SET @@session.net_write_timeout = 1; SELECT @@session.net_write_timeout; SET @@session.net_write_timeout = 50050; SELECT @@session.net_write_timeout; SET @@session.net_write_timeout = 65535; SELECT @@session.net_write_timeout; --echo '#------------------FN_DYNVARS_112_05-----------------------#' ############################################################# # Change the value of net_write_timeout to an invalid value # ############################################################# SET @@global.net_write_timeout = 0; SELECT @@global.net_write_timeout; SET @@global.net_write_timeout = -1024; SELECT @@global.net_write_timeout; SET @@global.net_write_timeout = 655360354; SELECT @@global.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@global.net_write_timeout = 65530.34; SELECT @@global.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@global.net_write_timeout = test; SELECT @@global.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@global.net_write_timeout = ' '; SELECT @@global.net_write_timeout; SET @@session.net_write_timeout = 0; SELECT @@session.net_write_timeout; SET @@session.net_write_timeout = -2; SELECT @@session.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@session.net_write_timeout = 65530.34; SET @@session.net_write_timeout = 6555015425; SELECT @@session.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@session.net_write_timeout = test; SELECT @@session.net_write_timeout; --Error ER_WRONG_TYPE_FOR_VAR SET @@session.net_write_timeout = ' '; SELECT @@session.net_write_timeout; --echo '#------------------FN_DYNVARS_112_06-----------------------#' #################################################################### # Check if the value in GLOBAL Table matches value in variable # #################################################################### --disable_warnings SELECT @@global.net_write_timeout = VARIABLE_VALUE FROM INFORMATION_SCHEMA.GLOBAL_VARIABLES WHERE VARIABLE_NAME='net_write_timeout'; --enable_warnings --echo '#------------------FN_DYNVARS_112_07-----------------------#' #################################################################### # Check if the value in SESSION Table matches value in variable # #################################################################### --disable_warnings SELECT @@session.net_write_timeout = VARIABLE_VALUE FROM INFORMATION_SCHEMA.SESSION_VARIABLES WHERE VARIABLE_NAME='net_write_timeout'; --enable_warnings --echo '#------------------FN_DYNVARS_112_08-----------------------#' #################################################################### # Check if TRUE and FALSE values can be used on variable # #################################################################### SET @@global.net_write_timeout = TRUE; SELECT @@global.net_write_timeout; SET @@global.net_write_timeout = FALSE; SELECT @@global.net_write_timeout; --echo '#---------------------FN_DYNVARS_112_09----------------------#' ################################################################################# # Check if accessing variable with and without GLOBAL point to same variable # ################################################################################# SET @@global.net_write_timeout = 10; SELECT @@net_write_timeout = @@global.net_write_timeout; --echo '#---------------------FN_DYNVARS_112_10----------------------#' ######################################################################################################## # Check if accessing variable with SESSION,LOCAL and without SCOPE points to same session variable # ######################################################################################################## SET @@net_write_timeout = 100; SELECT @@net_write_timeout = @@local.net_write_timeout; SELECT @@local.net_write_timeout = @@session.net_write_timeout; --echo '#---------------------FN_DYNVARS_112_11----------------------#' ############################################################################ # Check if net_write_timeout can be accessed with and without @@ sign # ############################################################################ SET net_write_timeout = 1; SELECT @@net_write_timeout; --Error ER_UNKNOWN_TABLE SELECT local.net_write_timeout; --Error ER_UNKNOWN_TABLE SELECT session.net_write_timeout; --Error ER_BAD_FIELD_ERROR SELECT net_write_timeout = @@session.net_write_timeout; #################################### # Restore initial value # #################################### SET @@global.net_write_timeout = @start_global_value; SELECT @@global.net_write_timeout; SET @@session.net_write_timeout = @start_session_value; SELECT @@session.net_write_timeout; ###################################################### # END OF net_write_timeout TESTS # ######################################################